IMPORTANT: Read all instructionsbefore installing or operating strobe. For continued protection againstelectrical shock, always connect the green or green/yellow (ground) wireto a suitable ground or plug into a grounded outlet.
WARNING: Never look directly into flash tube! Always unplug the strobe from its power source and allow ample time for the lamp to cool before replacing! Replace only with Diversitronics, Inc. #6091 Lamp. Hazardous voltage inside. Do not exposeto rain or moisture. Do not remove any screws or cover! Not for residentialuse. Keep front of strobe at least 3 feet from any flammable material. Alwaysuse safety cables when mounting fixtures. Never run power control wiresin the same conduit. Always refer servicing to qualified service personnel!
The PAR 56 and 64 strobe modules are designed to be installed into standard theatrical PAR cans (56 or 64).
ANALOG INPUT JACK: Analog input is connected to the strobe through this four pin modular handset jack. The Diversitronics Model RC-A singlechannel remote control plugs directly into this jack. Buy any 0-10 voltcontrol source can be connected to this input using the following pin assignments:(two pigtails are provided with each unit) (The +12v source, pin 3, canbe used for stand alone mode)
Yellow
Green
Red
BlackPin 1 = Intensity control (Do notexceed 24 volts on any input)
Pin 2 = Rate control
Pin 3 = +12 Volt (50ma Source)
Pin 4 = Common
ANALOG OUTPUT JACK: This jack provides a convenient way to daisy-chain the analog signal to several strobes from one controller. All inputs except Pin 3 (+12v Source) are fed through to the output connector. The maximumnumber of strobes that can be daisy-chained is ten. Max cable length 1000feet.
Diversitronics has modular connectors, cable, and tools available to make your own connecting cables. These parts are also available throughelectronic parts distributors. Contact factory for part numbers. Optionalsingle channel (RC-A), stand alone (ALC), and 4 channel (PS4M-A) controlsare available.
DMX INPUT CONNECTOR: This (standard DMX) 5-pin XLR connectorinputsthe DMX signal to the strobe.
DMX OUTPUT CONNECTOR: This (standard DMX) 5-pin XLR connector provides signal thru DMX source to additional DMX loads. An End-of-line terrminator resistor of 100-120 ohm is recommended.
DMX CHANNEL SELECT DIP SWITCH: This sets the strobe to respond to a given pair of DMX channels. Set it to the DMX channel you want thestrove Intensity Control to respond. Rate control will automatically respondto the next channel. For example, if you want the strobe to respond to DMXchannels 148 (Intensity) & 149 (Rate) set DIP switch as follows:
| DIP SWITCH | OFF |
ON |
||
| # | 256 | |||
| # | 128 | |||
| # | 64 | |||
| # | 32 | 128 | ||
| # | 16 | + 16 | ||
| # | 8 | + 4 | ||
| # | 4 | ---------- | ||
| # | 2 | 148 | ||
| # | 1 |
When the DIP switch is set to zero (all off) the strobe will be locked in the analog mode and will ignore DMX inputs.
SINGLE FLASH OPERATION: Can be performed in analog or DMX modes by keeping the rate input at zero and going from zero to some positive value on the intensity input. The strobe will then flash once at the intensityvalue inputted.
HOW HYPERFLASH WORKS: Hyperflash is controlled by the rate input channel onoy. The intensity channel must be off to be in the Hyperflashmode. Any positive input on the intensity channel will deactivate Hyperflashand the strobe will return to normal operation.
With the intensity channel set to zero, bumping the rate channel toagiven level (see table) will trigger a HyperBlast flash in one of 5 modes(see table). The rate channel must return to zero before another HyperBlastcan be activated.
| Rate Input Level | HYPERBLAST MODE | Recycle Time | ||
| 1 - 20% | Continuous | Continuous | ||
| 21 - 40% | Lightning | 1/2 second | ||
| 41 - 60% | Fade Off | 1.4 seconds | ||
| 61 - 80% | Crossfade | 2.25 seconds | ||
| 61 - 100% | Hyperflash | 1/2 second |
Proper planning & the correct number of fixtures can guarantee continous HYPERFLASH chase sequences without interruption.
POWER LED: This LED lights when main power is applied to thestrobe.
TEMP / STATUS LED: This LED stays on continously when a temperature overload exists (the internal temperature of the strobe exceeds 55 degrees C). Under this condition, the strobe automatically shuts off. When no overload exists, the LED blinks when an input signal is present. If the LED blinks but the strobe does not flash, a bad lamp or faulty power supply could exist.